Measurement | Control | Dosing | Disinfection
Measurement | Control | Dosing | Disinfection

Hydrogen Peroxide Sensor MWP7

Sensor for the measurement of hydrogen peroxide, with surfactant-resistant membrane.

Product description:

 

  • Measurement: Hydrogen peroxide,
  • Calibration: at the controller, analytical determination by DPD-method,
  • Interferences:

                        - Cl2 must not be existent,

                        - Peroxyacetic acid C2H4O3 must not be existent,

                        - O3 must not be existent,

                        - Sulfides must not be existent,

                        - Phenoles aquaous solution >3 % must not be existent,

  • pH range: 2 ... 11,
  • Pressure range: 0 ... 1 bar, no pressure surges and/or fluctuations,
  • Temperature range: 0 ... 45 °C,
  • Itengrated automatic temperature compensation,
  • Response time: T90 approx. 5 ... 10 min,
  • Flow rate: approx. 30 l/h, low flow-dependence,
  • Shaft length: 175 mm, mA-version 220 mm,
  • Connection: standard 4-pole plug, mA-version 2-pole terminal or M12 male, Material: PVC-U, stainless steel 1.4571 

 

Area of applications:

   

• Fresh water, tensides are tolerated

 

 

Scope of supply:

 

• MWP7: sensor, membrane cap, electrolyte

DOWNLOAD - 2016 MWC Hydrogen Peroxide Sensor MWP7 / Order- and Technical Data Sheet
16_MWC Hydrogen peroxide Sensor MWP7.pdf
PDF-Dokument [296.6 KB]
DOWNLOAD - 2016 MWC Hydrogen Peroxide Sensor MWP7 / Instruction Manual
110_MWC Instruction Manual MCD7_MP7_MOZ7[...]
PDF-Dokument [844.7 KB]
Druckversion Druckversion | Sitemap Diese Seite weiterempfehlen Diese Seite weiterempfehlen